Mechanical Diaphragm Metering Pump Selection Parameters and Methods of Use

First, the electromagnetic Diaphragm Metering Pump Mechanical Diaphragm Metering Pump Metering Pump selection parameters:



1. Is the measurement of liquid flow.

2. Measured the main characteristics of the liquid, such as chemical corrosion, viscosity and specific gravity. System back pressure.

3.suitable suction height.

4. Other options required, such as analog control, pulse control, flow monitoring and timer.



Second, the electromagnetic diaphragm metering pump mechanical diaphragm metering pump What are the main advantages? Electromagnetic drive metering pump only a moving parts - armature shaft. Generally, the less moving parts, the more reliable the metering pump works. Metering pump is ideal for low-flow, low-pressure workplaces, and good compensation in the supply voltage fluctuations. What are the advantages of metering pumps with fixed stroke length and varying frequency compared to metering pumps with fixed frequency and varying stroke length? With this correction, the dosing amount per stroke is known. The total dosage can therefore be calculated (dosing = dosing per stroke * frequency). The total dosage is linear with frequency (50% frequency = 50% dosing). Through external pulse or analog control, dosage can be transferred from minimum to maximum in one second. In addition, it is much less costly than motor-driven stroke length adjustment.

Third, how the electromagnetic diaphragm metering pump mechanical diaphragm metering pump performance curve?

1. Find the selected metering pump performance curve.

2. Indicate the current back pressure in the chart below.

3. Determine the correction factor, taking the backpressure value in bar, up to the curve, and read the correction factor vertically left at the intersection. Vortex Flowmeter
4. Divide the amount of dosing required by the correction factor to give the value in ml / min. Or L / h. Put the calculation result in the middle of the dosage scale.
5. When placing this value on the dosing scale, use a ruler to find the stroke length setting and stroke frequency setting.