How to replace diaphragm and crossheaded oil seal


01

First unscrew the six pump head connecting screws and remove the pump head

1


02

Use a special wrench to insert into the 2 holes at the outer end of the diaphragm cap

2


03

and turn counterclockwise to remove the diaphragm assembly

3


4


5


04

Disassemble the diaphragm assembly with a special wrench and adjustable wrench

6


05

Use a hexagon wrench to remove the screw at the connection seat of the pump head

7


06

Then gently rotate left and right to slowly pull out the pump head connection seat

Take out the original damaged oil seal

8


07

Then install the new oil seal into the pump head connection seat according to the direction of the opening towards the transmission box

9


08

Finally put the pump head connection seat back into the pump head

10


11


09

Reinstall the diaphragm assembly in the original order

12


13


10

Put the pump head back into the pump body

14


Contact Us

Author:

Ms. LUO TING

Phone/WhatsApp:

+86 13958523160

Popular Products
You may also like
Related Information
How to distinguish between single screw pump, twin screw pump and three screw pump

How to distinguish single screw pump, twin screw pump and three screw pump: As the name suggests, a single screw pump is only a screw in the pump. Follow the habits of China's screw industry, naming,...

High temperature control valve selection

High temperature control valve is the working temperature is greater than 450 ℃ valve. Can be divided into 450 ~ 600 ℃, 600 ~ 700 ℃, 750 ℃ three categories. What are the main problems usually...

Float level gauge points of use

Float level gauge is widely used in liquid level, chemical industry, metallurgy, electric power, paper making, food and industrial sewage treatment and other departments. By the magnetic reed switch,...

Valve actuator you choose right?

Because more and more factories use automatic control, manual operation is replaced by mechanical or automation equipment, the executive body is required to act as an interface between the control...

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be between 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send