1. Confirm the pressure
The Metering Pump rated pressure selected should be higher than the actual maximum pressure required, usually 10 to 20% higher; too much pressure will cause energy waste and increase the operating cost of the equipment.
2. Confirm the flow rate
The metering pump flow rate selected should be equal to or slightly higher than the required flow rate. The flow range of the metering pump is better during 30 to 100%, at this time the metering pump repetition accuracy is high. Considering the economic and practical , it is recommended that the actual flow rate of the metering pump is selected as 70-90% of the rated flow rate of the metering pump.

3.Confirm the material of the pump head (hydraulic end)
After the specific model is confirmed, then need select the material of wet parts according to the properties of the overflow medium.This step is very important,if not selected properly, it will cause medium corrosion and damage to the wet parts or medium leakage . Or even might cause major accidents.


4.Accuracy Grade
When selecting a metering pump,it is also necessary to consider the accuracy grade. The accuracy grade is higher,the input is greater. The general operating temperature of metering pump is -30 ~ 100℃, special metering pump has a wider operating temperature range (such as high-temperature liquid metering pump with insulation jacket, its conveying temperature can reach 500℃). For the particle size of the medium, the requirement should be less than 0.1mm. For medium greater than 0.1mm, can be targeted to change the flow structure of the pump, to meet the needs. The viscosity of the medium generally should be in 0 ~ 1000mm/s, special metering pumps can reach 6000mm2/s.


October 03, 2023
How to distinguish single screw pump, twin screw pump and three screw pump: As the name suggests, a single screw pump is only a screw in the pump. Follow the habits of China's screw industry, naming,...
High temperature control valve is the working temperature is greater than 450 ℃ valve. Can be divided into 450 ~ 600 ℃, 600 ~ 700 ℃, 750 ℃ three categories. What are the main problems usually...
Float level gauge is widely used in liquid level, chemical industry, metallurgy, electric power, paper making, food and industrial sewage treatment and other departments. By the magnetic reed switch,...
Because more and more factories use automatic control, manual operation is replaced by mechanical or automation equipment, the executive body is required to act as an interface between the control...
Email to this supplier
October 03, 2023
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.