Mechanical Diaphragm Dosing Pump
Hydraulic Diaphragm Metering Pump
Select Language
English
Fault finding and troubleshooting for hydraulic diaphragm metering pumps
Metering pump in the process of use, due to friction, external forces, stress and chemical reactions, parts will always gradually wear and corrosion, fracture, and therefore lead to failure and downtime. The following is a compilation of common faults and troubleshooting methods
Why is the diaphragm of a diaphragm pump easily damaged?
Diaphragm life times generally in 8 million ~ 20 million times, if used correctly, according to the minimum value can be used continuously 1000 hours ~ 3000 hours or so, in actual use diaphragm pump diaphragm often damaged. In the process of import and export of materials, the diaphragm left and right sides are subjected to forces up to 4800kN, due to the role of continuous alternating forces, making the diaphragm prone to damage cracking, the diaphragm is prone to damage for the following...
The Economic Situation Analysis Conference in Taizhou City in the third quarter and the "three comparisons and three views" supervision and evaluation conference have been held. From October 26 to 27, the main leaders of the city and county at all levels came to Sanmen County, Tiantai County and Xianju County to inspect the "three comparisons and three views" and conduct a focused exchange, mobilizing the city's people to break through the difficulties and fight into the fourth quarter to...
[Metering Pump Tips] What should I pay attention to when using a metering pump for the first time?
When using the metering pump for the first time, attention should be paid to the flow calibration and standardization, metering pump in the factory are after normal temperature clear water performance test, and the test results and flow calibration curves are also listed in the certificate of conformity.e. The user should test and calibrate the pump after the first 12 hours of operation to obtain the accuracy of the pump flow in a given operating condition. Pre-start preparation and checks 01...
[Metering Pump Maintenance Tips] Preventive Maintenance Of AILIPU J-series Mechanical Diaphragm Pump
Preventive maintenance of metering pumps can improve the efficiency of safe pump operation, extend the service life of the equipment, can reduce or avoid the normal use of the pump due to the failure of certain equipment. Ailipu J series mechanical diaphragm pump preventive maintenance can start from the following aspects. J-series Mechanical Diaphragm pump 1. Transmission Part The gear oil shall be changed after the initial operation for one month, and the lubricating oil in the transmission...
[Metering Pump Tips] Installation of metering pumps and piping requirements
1. The pump should be installed on a solid, vibration-resistant foundation, which should preferably be above ground level to avoid being washed by water and to facilitate maintenance; there should be sufficient space around the pump to facilitate maintenance, adjustment and oil filling and draining. 2. Pumps installed outdoors should be protected. 3. The installation position of the metering pump is as close as possible to the solution tank to reduce the loss of the metering pump suction line....
Dosing Method and Choice of Method for Dosing Units
Dosing method for dosing units 1. Inclusion of scale and corrosion inhibitors Add the agent to the washed dosing bucket according to the amount, add supplementary water under constant stirring to dilute the agent about 3 to 5 times (the purpose of dilution is to balance the dosing time, according to the need can also be undiluted), after stirring and mixing, turn on the dosing pump to adjust the dosing valve, so that the agent is continuously and evenly added to the catch basin, and control...
AILIPU is specialized in Metering pumps, Process hydraulic diaphragm pumps and Chemical dosing skids.Our live stream will be operated on October 11th from 7:00 to 11:00 p.m Beijing Time total 4 hours.Welcome to our live stream, whoever come to the live stream will receive a big big and huge surprise!If you want to know more about us,don't miss this opportunity, I hope you guys can be satisfied during that live! Set the time and see you guys! AILIPU LIVE SHOW LINk...
How to Deal with The Common Faults of Metering Pump?
Metering pump is a special positive displacement pump which can meet the needs of various strict technological processes, and the flow can be adjusted steplessly within 0 - range. It is used to transport liquids (especially corrosive liquids).With the continuous development of modern industry towards automatic operation and remote automatic control , the advantages of strong matching and wide adaptability to media (liquid) of metering pump are particularly prominent. In the long-term use of the...
Technical Applications | Analysis of the real causes of pump failure
There is a common misconception in wastewater applications that the pump is always the source of the problem when it stalls. In fact, many failures are caused by the influence of the system on the pump, other external environmental or operational factors. As the pump is critical to the wastewater system, it is wise to do more system failure analysis for anomalous or recurring failures. The cost and time required to get to the core issue may be lower than people think, and application...
In September, Ailipu is full of firepower. Colleagues in the dosing skid department have been busy assembling, inspecting, packaging, and shipping. Due to the large number of orders recently, the dosing-skid centre adjusted its work time and worked overtime to complete the production schedule, which fully demonstrates the good style of Ailipu people striving for excellence. Today, the superior product ordered by Shanghai customers-the H136 micro-channel reaction device production line has been...
When metering liquids, air bubbles and pressure fluctuations are the main reasons of inaccurate metering. Degassing media can also block the conveying process. The intelligent functions and model-based control of Solenoid diaphragm dosing pumps provide remedies for this. During the dosing process, air bubbles may appear in the suction pipe or in the dosing pump head. This situation occurs when dosing degassing medium such as sodium hypochlorite. Due to the presence of a certain amount of gas in...
Technical application | What is the valve opening pressure and how to deal with it correctly?
The output pressure of the metering pump is determined by the load and is approximately proportional to the input torque. There are two kinds of faults for abnormal output pressure: the output pressure is too low or the output pressure is too high. Valve opening pressure, which can be described as the pressure difference measured between the valve inlet and outlet when flow is initially detected. Specifically, opening pressure is the minimum pressure difference that the valve will experience...
The Driving End and Hydraulic End of Three-Plunger Diaphragm Pump
What is the three-plunger diaphragm pump and what are its features? Based on years of experience, Ailipu has developed and produced reciprocating diaphragm pumps based on reciprocating pumps and diaphragm metering pumps, and has now formed a series of products. This series of products is a horizontal single-acting or double-acting reciprocating hydraulic diaphragm pump. By means of the diaphragm element, the conveying slurry is completely isolated on the side of the medium flow channel, so that...
[Maintenance Tips] Maintenance of Ailipu Metering Pumps
Just like the human body, machines need to be carefully maintained and cared for.The premise and foundation of the use of mechanical equipment is the daily maintenance. 01 The oil level in the transmission box should be observed regularly, not too much but not too little Lubricant supply for AILIPU Metering Pump 02 The temperature of the main parts of the pump is specified as follows: The maximum acceptable temperature of the motor is 70°C, and the temperature of the lubricating oil in the...
Monitoring system of Three-Plunger Diaphragm Pump
The three-plunger diaphragm pump is developed by Ailipu based on years of experience in reciprocating pumps. It consists of driving end, plunger combination, hydraulic end and other parts. It is mainly used for the transportation of oilfield sewage and other medium. Let's learn about the monitoring system of the three-plunger diaphragm pump! The pump group monitoring system of the three-plunger diaphragm pump is composed of dry-type transformer, AC frequency conversion cabinet, local control...
Autumn is a colorful season. The Ailipu staff welcomed the joy of harvest and were busy loading and shipping.This set of equipment is a chemical dosing skid specially manufactured for oil and gas exploration projects. This equipment has a double-layer structure. The top layer is the storage tank and the bottom layer is the skid pipeline. The overall layout is compact and the operating space is maximized. The dosing pump in the skid accounts for 80%; the number of pipeline components is large;...
[Maintenance Tips] Installation of Ailipu Metering Pumps
In this issue, I specially summarize some knowledge about pump installation for you to ensure that the pump can run more efficiently, safely and stably. 01 The pump should be installed on a dedicated spare concrete foundation or cast iron platform. After correction, fix it with anchor bolts, and the concrete foundation should be 50~100 mm higher than the ground to prevent the water from rushing. Reserve enough space around the pump to facilitate maintenance and adjustment of the pump. 02 The...
AILIPU J1.6 Series Metering Pump Troubleshooting
How to replace the inlet & outlet valves 01 First close the inlet and outlet pipeline valves and then disassemble the inlet and outlet pipelines 02 Then use a wrench to unscrew the inlet and outlet valves and take out the valve assembly from the valve body 03 Check the valve ball and valve seat for any damaged or dirt blocked If there is any dirt, please wash it in clean water If the valve seat was damaged, please replace it with a new one 04 When assembling, please pay attention to the...
AILIPU JXM-A Metering Pump Troubleshooting 2.0
How to replace handwheel oil seal 01 Drain the gearbox oil 02 Take out the nameplate on the handwheel 03 Use a crossheaded screw to unscrew the handwheel fixing screw and take out the handwheel 04 Unscrew the connecting screw of the adjusting rod seat and the casing 05 Disassemble the adjusting rod seat 06 Lay the adjusting rod seat flat on the table Use circlip pliers to take out the circlip 07 Take out the oil seal 08 Reinstall the new oil seal 09 Replace the circlip 10 adjusting rod seat and...
AILIPU JXM-A Metering Pump Troubleshooting 3.0
How to replace diaphragm and crossheaded oil seal 01 First unscrew the six pump head connecting screws and remove the pump head 02 Use a special wrench to insert into the 2 holes at the outer end of the diaphragm cap 03 and turn counterclockwise to remove the diaphragm assembly 04 Disassemble the diaphragm assembly with a special wrench and adjustable wrench 05 Use a hexagon wrench to remove the screw at the connection seat of the pump head 06 Then gently rotate left and right to slowly pull...
AILIPU JXM-A Metering Pump Troubleshooting 1.0
How to check and replace inlet and outlet valves 01 First close the inlet and outlet pipeline valves and then disassemble the inlet and outlet pipelines 02 Then use a wrench to unscrew the inlet and outlet valves and take out the valve assembly in the valve body 03 Check the valve ball and valve seat for any damaged or dirt stucked 04 If there is any dirt, please wash it in clean water If the valve seat is damaged, please replace it with a new one 05 When assembling, please pay attention to the...
AILIPU JWM-A Metering Pump Troubleshooting 1.0
Let's talk about how to replace JWM-A diaphragm. 1.Use an inner hexagon wrench to unscrew the bolts at the connection of the pump head and disassemble the pump head. 2.Unscrew the diaphragm counterclockwise 3. If the diaphragm is damaged, replace it with a new one. 4. Screw the new diaphragm clockwise on the pump body. 5. Install the pump head back into the pump body with the outlet facing up and the inlet facing down. 6. Screw on the pump head connecting bolts respectively.
AILIPU JWM-A Metering Pump Troubleshooting 2.0
How to replace inlet and outlet valves 1. Disassemble the joint pressure cap on the check valve and remove the O-Ring from the check valve 2. Take out the check valve spool 3. Unscrew the valve body counterclockwise with an adjustable wrench 4. Put the 2 valve spools into the valve body respectively.The direction of the "triangle aim point" of the outlet check valve is consistent with the direction of the large end of the valve body, the "triangle aim point" direction of the inlet check valve...